SPECIFICATION
| Parameter | Details |
| Measurement Range | -100kPa…0~5kPa…60MPa |
| Overload pressure | 1.5 times of the rated pressure |
| Accuracy | ±0.5%F.S(-100kPa…0~5kPa…60MPa) ±0.25%F.S(-100kPa…0~10kPa…60MPa) |
| Stability | <0.5%F. S/year |
| Working Temp | -20~85°C |
| Storage Temp | -40~100°C |
| Measured Medium | Gas or liquid compatible with 304 and 316L stainless steel, Fluorine rubber or Nitrile rubber |
| Electrical Properties | 2-wired (current): • Output Signal: 4~20mA • Power Supply: 8~36VDC 3-wired (voltage): • Output Signal: 0.5~4.5V | Power Supply: 4.75~5.25VDC • Output Signal: 0~5V | Power Supply: 8~36VDC • Output Signal: 0~10V | Power Supply: 12~36VDC 4-wired: • Output Signal: RS485 • Power Supply: 10~30VDC |
| Electrical Connection | DIN43650A (Big Hirschmann), M12 waterproof outlet, GX12 aviation connector (three-core/four-core), M12 four-core aviation connector |
| Enclosure Protection | IP54 (GX12 aviation connector), IP65 (DIN43650A, M12 waterproof outlet, M12 four-core aviation connector) |
| Pressure Connection | G1/4, NPT1/4, R1/4, G1/2, 7/16-20UNF, M20*1.5, M10*1, M14*1.5 etc |
| Pressure Form | Gauge Pressure G/Absolute Pressure A |
| Certification | RoHS, EU electrical safety standard CE |